[Rivet] HepMC units in AGILeAndy Buckley andy.buckley at ed.ac.ukWed Apr 21 23:37:10 BST 2010
On 21/04/10 17:29, Frank Siegert wrote: > Hi guys, > > I have the bad suspicion that AGILe doesn't respect the default HepMC > units when filling HepMC events. When using AGILe compiled with > HepMC from GENSER it produces events that claim to have MEV/MM units, > but the numbers are still GEV numbers (e.g. E=900 for a Tev-I beam). > > Am I wrong in my diagnosis (and have just killed 230 jobs in vain) or > is this indeed a relatively serious problem because the bootstrap > script uses HepMC 2.05 from GENSER by default? Could be a serious problem... I can't remember if AGILe is specifying the HepMC units properly, since the experiment version was always a blocker on what was done. I think that Rivet should handle the incoming HepMC units properly, but AGILe quite possibly doesn't write them. One to fix -- asap -- before a new AGILe release. I'll take a look at it tomorrow. Andy -- Dr Andy Buckley SUPA Advanced Research Fellow Particle Physics Experiment Group, University of Edinburgh