[Rivet] Rivet 1.8.3b1 available for mcplots testing

Anton Karneyeu anton.karneyeu at cern.ch
Mon Apr 8 11:17:42 BST 2013


Hi Andy,

sorry for late reply.
I have tested the 1.8.3b1 and do not see any problems.

The only thing I would like to point is the large number of error 
messages concerning unknown PID in analyses LHCB_2010_S8758301, 
LHCB_2011_I917009 and LHCB_2012_I1119400.
Attached file is the summary on the rates of errors (2nd column is the 
error message and 1st column is number of times it appears) over all 
runs of 100k events default tune of all generators/versions which we 
have in mcplots. Could you please have a look?

And I will prepare separate mail on AGILe/Alpgen questions.

Cheers,
Anton




2013-04-04 11:04, Andy Buckley wrote:
> Hi again Anton,
>
> Have you had a chance to do this testing yet? And any feedback re Alpgen
> in AGILe?
>
> Thanks,
> Andy
>
>
> On 23/03/13 17:46, Andy Buckley wrote:
>> Hi Anton,
>>
>> We finally have that promised new version of Rivet 1.8.x for you to
>> test! A new 1.8.3b1 tarball is available as usual at
>> http://www.hepforge.org/downloads/rivet -- could you please try it out
>> and let us know if you seen any obvious problems? Thanks once again :)
>>
>> Andy & co
>>
>> PS. You asked about getting Alpgen working with PYTHIA6 in 64 builds of
>> AGILe. I've not seen the problem myself, but as we discussed if you can
>> send a stand-alone example that works and/or a stack trace, we'll try to
>> help with debugging / providing a fixed version.
>>
>
>
-------------- next part --------------

     29 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 102142... This K_s^0 will be considered unprompt!
     25 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 102144... This K_s^0 will be considered unprompt!
    428 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 103214... This K_s^0 will be considered unprompt!
    966 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 103224... This K_s^0 will be considered unprompt!
     30 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 103314... This K_s^0 will be considered unprompt!
    399 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 103324... This K_s^0 will be considered unprompt!
   1217 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 13322... This K_s^0 will be considered unprompt!
    645 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 203122... This K_s^0 will be considered unprompt!
    767 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 203212... This K_s^0 will be considered unprompt!
    923 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 203222... This K_s^0 will be considered unprompt!
    118 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 203312... This K_s^0 will be considered unprompt!
    322 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 203322... This K_s^0 will be considered unprompt!
    129 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 23322... This K_s^0 will be considered unprompt!
     15 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 9900441... This K_s^0 will be considered unprompt!
      8 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 9900443... This K_s^0 will be considered unprompt!
      6 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 9900551... This K_s^0 will be considered unprompt!
 174097 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 9902210... This K_s^0 will be considered unprompt!
 188698 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 990... This K_s^0 will be considered unprompt!
     29 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 9910441... This K_s^0 will be considered unprompt!
      1 Rivet.Analysis.LHCB_2010_S8758301: ERROR  Could not determine lifetime for particle with PID 9910551... This K_s^0 will be considered unprompt!
      
  23807 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 102132... This V^0 will be considered unprompt!
    838 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 102142... This V^0 will be considered unprompt!
    683 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 102144... This V^0 will be considered unprompt!
   1037 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 103112... This V^0 will be considered unprompt!
  15737 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 103114... This V^0 will be considered unprompt!
   9558 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 103212... This V^0 will be considered unprompt!
  24070 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 103214... This V^0 will be considered unprompt!
   1624 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 103222... This V^0 will be considered unprompt!
  26548 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 103224... This V^0 will be considered unprompt!
   4484 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 103314... This V^0 will be considered unprompt!
   6567 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 103324... This V^0 will be considered unprompt!
  24861 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 13312... This V^0 will be considered unprompt!
  28111 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 13322... This V^0 will be considered unprompt!
      5 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 14312... This V^0 will be considered unprompt!
     15 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 14322... This V^0 will be considered unprompt!
     31 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 15122... This V^0 will be considered unprompt!
      1 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 15322... This V^0 will be considered unprompt!
   5916 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 203112... This V^0 will be considered unprompt!
   8786 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 203122... This V^0 will be considered unprompt!
  13026 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 203212... This V^0 will be considered unprompt!
  15564 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 203222... This V^0 will be considered unprompt!
   3766 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 203312... This V^0 will be considered unprompt!
   5084 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 203322... This V^0 will be considered unprompt!
   2308 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 23312... This V^0 will be considered unprompt!
   3469 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 23322... This V^0 will be considered unprompt!
   3488 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 9020221... This V^0 will be considered unprompt!
     34 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 9900441... This V^0 will be considered unprompt!
     88 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 9900443... This V^0 will be considered unprompt!
      6 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 9900551... This V^0 will be considered unprompt!
      2 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 9900553... This V^0 will be considered unprompt!
 777028 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 990... This V^0 will be considered unprompt!
     81 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 9910441... This V^0 will be considered unprompt!
     11 Rivet.Analysis.LHCB_2011_I917009: ERROR  Could not determine lifetime for particle with PID 9910551... This V^0 will be considered unprompt!
     
   2169 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 102112... This will be considered unprompt!
   1696 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 102132... This will be considered unprompt!
    361 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 102142... This will be considered unprompt!
    271 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 102144... This will be considered unprompt!
  18837 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 102212... This will be considered unprompt!
  18760 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 10221... This will be considered unprompt!
    514 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 103112... This will be considered unprompt!
   1911 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 103114... This will be considered unprompt!
    711 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 103212... This will be considered unprompt!
   2195 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 103214... This will be considered unprompt!
    637 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 103222... This will be considered unprompt!
   2219 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 103224... This will be considered unprompt!
    564 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 103314... This will be considered unprompt!
    100 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 103324... This will be considered unprompt!
   1803 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 13312... This will be considered unprompt!
    581 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 13322... This will be considered unprompt!
      8 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 14312... This will be considered unprompt!
      4 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 14322... This will be considered unprompt!
      4 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 15122... This will be considered unprompt!
      2 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 15312... This will be considered unprompt!
   2521 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 202112... This will be considered unprompt!
  17565 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 202212... This will be considered unprompt!
   1138 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 203112... This will be considered unprompt!
   2048 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 203122... This will be considered unprompt!
   1159 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 203212... This will be considered unprompt!
   1508 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 203222... This will be considered unprompt!
    388 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 203312... This will be considered unprompt!
    182 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 203322... This will be considered unprompt!
    403 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 23312... This will be considered unprompt!
    153 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 23322... This will be considered unprompt!
   5800 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 9020221... This will be considered unprompt!
     63 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 9900441... This will be considered unprompt!
    119 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 9900443... This will be considered unprompt!
      6 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 9900551... This will be considered unprompt!
     24 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 9900553... This will be considered unprompt!
 898251 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 990... This will be considered unprompt!
    132 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 9910441... This will be considered unprompt!
     18 Rivet.Analysis.LHCB_2012_I1119400: ERROR  Could not determine lifetime for particle with PID 9910551... This will be considered unprompt!


More information about the Rivet mailing list